污水處理設備 污泥處理設備 水處理過濾器 軟化水設備/除鹽設備 純凈水設備 消毒設備|加藥設備 供水/儲水/集水/排水/輔助 水處理膜 過濾器濾芯 水處理濾料 水處理劑 水處理填料 其它水處理設備
上海朕鋅電氣設備公司
參 考 價 | 面議 |
產(chǎn)品型號6ES7 416-2XN05-0AB0
品 牌
廠商性質(zhì)經(jīng)銷商
所 在 地上海市
聯(lián)系方式:田敏查看聯(lián)系方式
更新時間:2018-06-05 01:09:40瀏覽次數(shù):162次
聯(lián)系我時,請告知來自 環(huán)保在線6ES7 416-2XN05-0AB0
CPU
16ES7211-0AA23-0XB0CPU221 DC/DC/DC,6輸入/4輸出
26ES7211-0BA23-0XB0CPU221 繼電器輸出,6輸入/4輸出
6ES7 416-2XN05-0AB0西門子PLC 6ES7 416-2XN05-0AB0西門子代理
西門子銷售
田敏(銷售工程師) 主營產(chǎn)品(西門子)SIEMENS
手機 可編程控制器(PLC) 人機界面(HMI)
數(shù)控伺服 工業(yè)以太網(wǎng)
傳真 數(shù)控系統(tǒng) 電線電纜
商務 2304334979 變頻器 伺服驅(qū)動
地址 上海市金山區(qū)楓蘭路128號 以上產(chǎn)品*,質(zhì)量保證!
CPU 416-2, CPU 416-3 and CPU 416-3 PN/DP are powerful SIMATIC S7-400 CPUs.
The integrated PROFIBUS DP interfaces in the CPU 416-2 and CPU 416-3 make it possible to connect directly to the PROFIBUS DP fieldbus as a master or slave.
An additional DP master system can be connected to the CPU 416-3 and CPU 416-3 PN/DP using the IF 964-DP interface module.
The integrated PROFINET interface of the CPU 416-3 PN/DP includes switch functionality when the ERTEC 400-ASIC is used. This forms the basis for providing two externally accessible PROFINET ports. In addition to hierarchical network topologies, this also enables the creation of line structures in the new S7-400 controllers.
Note:
Only the 6ES7 964-2AA04-0AB0 interface submodule may be used.
Both CPUs are equipped with the following:
CPU 416-3 and CPU 416-3 PN/DP also include:
CPU 416-3 PN/DP additionally includes:
CPU 416-3 PN/DP additional:
Parameterizable attributes
The STEP 7 tool "Hardware Configuration" can be used to program the properties and response of the S7-400 including the CPUs, e.g.
CPU 416-3 PN/DP additional:
Indication and information functions
Order number | 6ES7416-2XN05-0AB0 | 6ES7416-3XR05-0AB0 | 6ES7416-3ES06-0AB0 | |
---|---|---|---|---|
CPU 416-2, MPI, PROFIBUS, 5.6 MB | CPU 416-3, 11.2 MB, 3 INTERFACES | CPU416-3 PN/DP, 16 MB, 3 INTERFACES | ||
Product type designation | ||||
General information | ||||
Engineering with | ||||
| STEP7 V 5.3 SP2 or higher with HW update | STEP7 V 5.3 SP2 or higher with HW update | STEP7 V5.5 or higher/iMap V3.0 + iMap STEP7 Add-on V3.0 SP5 or higher | |
Supply voltage | ||||
Rated value (DC) | ||||
| No; Power supply via system power supply | No; Power supply via system power supply | ||
Power losses | ||||
Power loss, typ. | 4 W | 5.5 W | 6.5 W | |
Memory | ||||
Work memory | ||||
| 5.6 Mbyte | 11.2 Mbyte | 16 Mbyte | |
| 2.8 Mbyte | 5.6 Mbyte | 8 Mbyte | |
| 2.8 Mbyte | 5.6 Mbyte | 8 Mbyte | |
Load memory | ||||
| 64 Mbyte | 64 Mbyte | 64 Mbyte | |
| 1 Mbyte | 1 Mbyte | 1 Mbyte | |
| 64 Mbyte | 64 Mbyte | 64 Mbyte | |
CPU processing times | ||||
for bit operations, typ. | 30 ns | 30 ns | 30 ns | |
for word operations, typ. | 30 ns | 30 ns | 30 ns | |
for fixed point arithmetic, typ. | 30 ns | 30 ns | 30 ns | |
for floating point arithmetic, typ. | 90 ns | 90 ns | 90 ns | |
IEC counter | ||||
| Yes | Yes | Yes | |
IEC timer | ||||
| Yes | Yes | Yes | |
Data areas and their retentivity | ||||
Flag | ||||
| 16 kbyte | 16 kbyte; Size of bit memory address area | 16 kbyte; Size of bit memory address area | |
Address area | ||||
I/O address area | ||||
| 16 kbyte | 16 kbyte | 16 kbyte | |
| 16 kbyte | 16 kbyte | 16 kbyte | |
Process image | ||||
| 16 kbyte | 16 kbyte | 16 kbyte | |
| 16 kbyte | 16 kbyte | 16 kbyte | |
Hardware configuration | ||||
Slots | ||||
| 1 | 2 | 2 | |
Time of day | ||||
Clock | ||||
| Yes | Yes | Yes | |
Operating hours counter | ||||
| 8 | 16 | 16 | |
Interfaces | ||||
Interface/bus type | 1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP, 1 x PROFIBUS DP (optionally pluggable) | 1 x MPI/PROFIBUS DP, 1 x PROFINET (2 ports), 1 x PROFIBUS DP (optionally pluggable) | ||
Number of RS 485 interfaces | 2 | 2 | 1 | |
Number of other interfaces | 0 | 0 | 0 | |
1st interface | ||||
Interface type | Integrated | Integrated | Integrated | |
Physics | RS 485 / PROFIBUS | RS 485 / PROFIBUS + MPI | RS 485 / PROFIBUS + MPI | |
Functionality | ||||
| Yes | Yes | Yes | |
| Yes | Yes | Yes | |
| Yes | Yes | Yes | |
DP master | ||||
| 32 | 32 | 32 | |
2nd interface | ||||
Interface type | Integrated | Integrated | PROFINET | |
Physics | RS 485 / PROFIBUS | RS 485 / PROFIBUS | Ethernet RJ45 | |
Number of ports | 2 | |||
Functionality | ||||
| Yes | Yes | No | |
| Yes | Yes | No | |
| Yes | |||
| Yes | |||
| Yes | |||
DP master | ||||
| 125 | 125 | ||
PROFINET IO Controller | ||||
| 256 | |||
| 256 | |||
| 64 | |||
3rd interface | ||||
Interface type | Pluggable interface module (IF), technical data as for 2nd interface | Pluggable interface module (IF) | ||
Plug-in interface modules | IF 964-DP (MLFB: 6ES7964-2AA04-0AB0) | IF 964-DP (MLFB: 6ES7964-2AA04-0AB0) | ||
Physics | RS 485 / PROFIBUS | RS 485 / PROFIBUS | ||
Functionality | ||||
| No | No | ||
| Yes | Yes | ||
| Yes | Yes | ||
DP master | ||||
| 125 | 125 | ||
Isochronous mode | ||||
Isochronous operation (application synchronized up to terminal) | Yes | Yes; For PROFIBUS only | Yes; Via PROFIBUS DP or PROFINET interface | |
Communication functions | ||||
PG/OP communication | Yes | Yes | Yes | |
Data record routing | Yes | Yes | ||
Global data communication | ||||
| Yes | Yes | Yes | |
S7 basic communication | ||||
| Yes | Yes | Yes | |
S7 communication | ||||
| Yes | Yes | Yes | |
S5-compatible communication | ||||
| Yes; (via CP max. 10 and FC AG_SEND and FC AG_RECV) | Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5 | Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5 | |
Standard communication (FMS) | ||||
| Yes; Via CP and loadable FB | Yes; Via CP and loadable FB | Yes; Via CP and loadable FB | |
Open IE communication | ||||
| Yes; via integrated PROFINET interface and loadable FBs | |||
| 94 | |||
| Via CP 443-1 Adv. and loadable FB | Via CP 443-1 and loadable FB | Yes; Via integrated PROFINET interface or CP 443-1 and loadable FBs | |
| 94 | |||
| Yes; via integrated PROFINET interface and loadable FBs | |||
| 94 | |||
Web server | ||||
| No; Via CP | No | Yes | |
Number of connections | ||||
| 64 | 64 | 96 | |
Configuration | ||||
programming | ||||
Programming language | ||||
| Yes | Yes | Yes | |
| Yes | Yes | Yes | |
| Yes | Yes | Yes | |
| Yes | Yes | Yes | |
| Yes | Yes | Yes | |
| Yes | Yes | Yes | |
| Yes | Yes | Yes | |
Know-how protection | ||||
| Yes | Yes | Yes | |
| Yes; With S7 block Privacy | |||
Dimensions | ||||
Width | 25 mm | 50 mm | 50 mm | |
Height | 290 mm | 290 mm | 290 mm | |
Depth | 219 mm | 219 mm | 219 mm | |
Weights | ||||
Weight, approx. | 720 g | 0.9 kg | 900 g |