日本KOMYOKK乙炔乙烯氣體檢測管280S
詳細(xì)介紹
日本KOMYOKK北川式乙炔乙烯分開測氣體檢測管280S
1. PERFORMANCE
1) Measuring range:
Acetylene 20-300 ppm
Ethylene 200-2000 ppm
Number of pump strokes 1(100mr)
2) Sampling time :3 minutes/1 pump stroke with orifice
3) Detectable limit :
Acetylene 0.1 ppm
Ethylene 1 ppm
4) Shelf life :1 year
5) Operating temperature :10~40℃
6) Temperature compensation:
Acetylene No temperature correction is necessary.
Ethylene Necessary(refer to "Table 2. Temperature CorrectionTable")
7) Reading :Direct reading from the scale calibrated by 1 pump stroke
8) Colour change:
Acetylene Yellow→Dark brown
Ethylene Pale yellow→Blue
2. RELATIVE STANDARD DEVIATION
RSD-low:10% RSD-mid.:10% RSD-high:10%
3. CHEMICAL REACTION
Acetylene detector tube:C2H2+K2Pd(SO3)2→Pd
Ethylene detector tube:C2H2+PdSO4+(NH4)2Mo3O5
4. CALIBRATION OF THE TUBE
STANDARD GAS CYLINDER METHOD
5. INTERFERENCE AND CROSS SENSITIVITY
GAS To pump
ppm
2000
ppm
1800
1600
1400
1200
1000
800
600
400
300
250
200
150
100
50
20
200
Tube No.
280S ACETYLENE ETHYLENE
TEMPERATURE CORRECTION TABLE
Tube Corrected Concentration (%)
Readings 10℃ 20℃ 30℃ 40℃
(ppm) (50°F) (68°F) (86°F) (104°F)
2000 1550 2000
1800 1400 1800 2050
1600 1300 1600 1900
1400 1150 1400 1600
1200 1000 1200 1400
1000 900 1000 1200
800 750 800 950
600 600 600 700
日本KOMYOKK乙炔乙烯氣體檢測管280S
日本KOMYOKK北川式乙炔乙烯分開測氣體檢測管280S,乙炔乙烯分開測氣體檢測管280S ACETYLENE?ETHYLENE HC≡CH、H2C=CH2 20-300ppm(C2H2),200-2,000ppm(C2H4)日本光明理化工業(yè)株式會(huì)社從1947年開始,在氣體分析領(lǐng)域開拓了六十余年 , 形成了于世的 ” 北川 ” 式氣體檢測管。氣體快速分析法 ” 北川 ” 的歷史就是日本檢測管的歷史 。目前是世界上zui大的檢測管生產(chǎn)廠家,也是日本*家通過美國SEI的認(rèn)證,歐盟的認(rèn)證的檢測管廠家。公司不僅有ISO9001:2000的認(rèn)證,還獲得了環(huán)境管理的ISO14001的認(rèn)證。北川式手動(dòng)氣體采集器AP-20 備有采氣完成指示計(jì) , 可以清楚的判明采氣是否完成 . • 有專門截留玻璃的截留槽 , 以防止檢測管割尖時(shí)玻璃片飛濺 . • 有采氣容積為 50 毫升和 100 毫升的兩段式制動(dòng)卡 . • 采氣器極為小巧 , 并有便于攜帶的皮具包 。